Project — Multi-Node CAN Network

Level 1's capstone was one node talking to a bench tool. Everything in Level 2 — mailboxes and filters, DMA, an RTOS, low power, flash, the bootloader, UDS — exists because real ECUs share a bus with modules written by other teams, booting at different times and failing independently. This project builds that: three nodes, one 500 kbit/s bus, a defined message catalogue, and a fault-handling matrix that states what each node does when any other goes quiet. The firmware is the easy half; the communication matrix and the timeout behaviour are the half that gets reviewed.

The system

A simplified cooling-fan subsystem:

                     CAN 500 kbit/s, 120 Ω at each end
     ┌────────────┬─────────────────┬─────────────────┬────────────┐
    120Ω          │                 │                 │           120Ω
           ┌──────┴──────┐   ┌──────┴──────┐   ┌──────┴──────┐
           │ SENSOR node │   │ACTUATOR node│   │GATEWAY node │
           │   S32K144   │   │   S32K144   │   │   S32K144   │
           ├─────────────┤   ├─────────────┤   ├─────────────┤
           │ NTC via ADC │   │ FTM PWM→fan │   │ Arbitrates  │
           │ 10 ms sample│   │ Tacho input │   │ Owns UDS    │
           │ TX 0x310    │   │ RX 0x311    │   │ TX 0x100/311│
           │ RX 0x100    │   │ TX 0x312    │   │ RX 0x310/312│
           └─────────────┘   └─────────────┘   └─────────────┘

The sensor measures, the gateway decides, the actuator drives. No node trusts another's liveness: each supervises the frames it consumes and has a defined fallback when they stop.

Message catalogue

Lower ID wins arbitration, so the ID allocation is the priority scheme.

ID Name Producer Consumers Period DLC
0x100 NetworkMode Gateway Sensor, Actuator 500 ms 2
0x200 NodeFault any Gateway event, ≥ 100 ms gap 4
0x310 SensorStatus Sensor Gateway 100 ms 8
0x311 ActuatorCommand Gateway Actuator 100 ms 4
0x312 ActuatorStatus Actuator Gateway 100 ms 6
0x7DF/0x7E0/0x7E8 UDS (module 9) tester / Gateway Gateway / tester on request ≤ 8

0x310 SensorStatus — Level 1's layout carried forward:

Bits Signal Type Scale Notes
0–15 CoolantTemp int16 0.1 °C −40.0…150.0 °C
16–31 SupplyVoltage uint16 1 mV Node's own rail
32 SensorValid bool Plausibility result
36–39 AliveCounter uint4 Wraps 0→15
48–55 Checksum uint8 XOR of bytes 0–6 plus the ID

0x311 ActuatorCommand carries FanTargetPct (uint8, 0–100), AliveCounter (uint4), RequestedMode (uint2: 0 normal, 1 degraded, 2 safe) and a checksum. 0x312 ActuatorStatus returns FanActualPct (uint8), FanSpeedRpm (uint16 from the tacho capture), AliveCounter, an OutputStageFault bit and a checksum. 0x100 NetworkMode carries a 2-bit mode (0 run, 1 degraded, 2 safe, 3 sleep-request) plus an alive counter; 0x200 NodeFault carries the reporting node's ID, a fault code and a fault counter.

Expected message flow

One healthy 100 ms cycle. The offsets are deliberate — if every node transmitted on its own 100 ms boundary they would collide every cycle and the lowest-priority frame would jitter systematically.

 t (ms)  0    10   20   30   40   50   60   70   80   90   100
         │    │    │    │    │    │    │    │    │    │    │
 Sensor  ├─0x310                                            ├─0x310
         │  ADC sampled every 10 ms, frame sent on the tick
 Gateway │    ├─0x100 (every 5th cycle)
         │         ├─0x311  built from the 0x310 seen at t=0
 Actuator│              ├─0x312  reports the PWM applied at t≈22 ms

The end-to-end latency the gateway must budget for:

sensor sample → 0x310 TX      ≤ 10 ms   (sampling phase)
0x310 on the wire             ≈ 0.26 ms (8-byte frame at 500 kbit/s)
gateway processes → 0x311     = 20 ms   (fixed offset)
0x311 on the wire             ≈ 0.26 ms
actuator applies PWM          ≤ 10 ms   (its own tick)
                              ─────────
worst case                    ≈ 41 ms

Write that number down — it is the first thing a systems engineer asks for, and it changes the moment anyone adds a queue. Bus load deserves the same treatment:

Frame Rate Worst-case bits Bits/s
0x310 (8 B) 10 Hz ~130 1300
0x311 (4 B) 10 Hz ~98 980
0x312 (6 B) 10 Hz ~114 1140
0x100 (2 B) 2 Hz ~82 164
Total ≈ 3.6 kbit/s → 0.7 % of 500 kbit/s

Worst-case bits include standard-frame overhead plus maximum bit stuffing. Under 1 % sounds like infinite headroom; the point of computing it is that when someone proposes a 20 ms trace frame carrying 64 bytes, you answer with a number instead of an opinion.

Shared definitions

Every node compiles the same header. That is not tidiness — it is how you guarantee three teams agree on byte 4.

/* can_matrix.h — shared by all three nodes, single source of truth */
#define ID_NETWORK_MODE      0x100u
#define ID_NODE_FAULT        0x200u
#define ID_SENSOR_STATUS     0x310u
#define ID_ACTUATOR_COMMAND  0x311u
#define ID_ACTUATOR_STATUS   0x312u

#define PERIOD_MS_STATUS     100u
#define TIMEOUT_MS_STATUS    300u    /* three missed cycles            */

typedef enum {
    NET_MODE_RUN = 0u, NET_MODE_DEGRADED = 1u,
    NET_MODE_SAFE = 2u, NET_MODE_SLEEP = 3u,
} net_mode_t;

/* The ID is folded in, so a frame delivered under the wrong identifier
   — a mis-set filter, a copy-paste in another node — fails the check
   instead of being silently accepted.                               */
static inline uint8_t can_checksum(uint16_t id, const uint8_t *d, uint8_t n)
{
    uint8_t c = (uint8_t)(id & 0xFFu) ^ (uint8_t)(id >> 8);
    for (uint8_t i = 0u; i < n; i++) { c ^= d[i]; }
    return c;
}

typedef struct {
    uint8_t  lastAlive;
    uint32_t age_ms;
    bool     valid;
} sig_health_t;

/* Called from each node's 10 ms task, once per consumed signal. */
static inline bool sig_supervise(sig_health_t *h, uint32_t timeout_ms)
{
    h->age_ms += 10u;
    if (h->age_ms > timeout_ms) { h->valid = false; }
    return h->valid;
}

Receiving with the RX FIFO

The gateway consumes three IDs, so it uses module 1's RX FIFO rather than three mailboxes and three interrupts:

static flexcan_state_t   canState;
static flexcan_msgbuff_t rxMsg;

static flexcan_id_table_t gwFilters[8] = {
    { .isRemoteFrame = false, .isExtendedFrame = false, .id = ID_SENSOR_STATUS   },
    { .isRemoteFrame = false, .isExtendedFrame = false, .id = ID_ACTUATOR_STATUS },
    { .isRemoteFrame = false, .isExtendedFrame = false, .id = ID_NODE_FAULT      },
    /* Pad with a repeat of a used ID — never 0x000, which would accept
       the highest-priority frame on the bus (module 1).              */
    { false, false, ID_NODE_FAULT }, { false, false, ID_NODE_FAULT },
    { false, false, ID_NODE_FAULT }, { false, false, ID_NODE_FAULT },
    { false, false, ID_NODE_FAULT },
};

static void gw_can_cb(uint8_t instance, flexcan_event_type_t event,
                      uint32_t buffIdx, flexcan_state_t *state)
{
    (void)buffIdx; (void)state;
    switch (event) {
    case FLEXCAN_EVENT_RXFIFO_COMPLETE:
        gw_queue_frame(&rxMsg);                    /* copy out, return */
        (void)FLEXCAN_DRV_RxFifo(instance, &rxMsg);
        break;
    case FLEXCAN_EVENT_RXFIFO_OVERFLOW:
        g_rxOverflows++;                           /* a frame was lost */
        break;
    default:
        break;
    }
}

void gw_can_init(void)
{
    flexcan_user_config_t cfg;
    FLEXCAN_DRV_GetDefaultConfig(&cfg);
    cfg.max_num_mb        = 16u;
    cfg.is_rx_fifo_needed = true;
    cfg.num_id_filters    = FLEXCAN_RX_FIFO_ID_FILTERS_8;
    cfg.flexcanMode       = FLEXCAN_NORMAL_MODE;
    cfg.payload           = FLEXCAN_PAYLOAD_SIZE_8;

    (void)FLEXCAN_DRV_Init(INST_CAN0, &canState, &cfg);
    (void)FLEXCAN_DRV_ConfigRxFifo(INST_CAN0,
                                   FLEXCAN_RX_FIFO_ID_FORMAT_A, gwFilters);
    FLEXCAN_DRV_SetRxFifoGlobalMask(INST_CAN0, FLEXCAN_MSG_ID_STD,
                                    (0x7FFu << 18));   /* exact match  */
    FLEXCAN_DRV_InstallEventCallback(INST_CAN0, gw_can_cb, NULL);
    (void)FLEXCAN_DRV_RxFifo(INST_CAN0, &rxMsg);
}

Validation happens in the task, never in the callback:

bool gw_accept_sensor_status(const flexcan_msgbuff_t *m)
{
    if (m->dataLen != 8u) { return false; }
    if (m->data[6] != can_checksum(ID_SENSOR_STATUS, m->data, 6u)) {
        g_checksumErrors++;
        return false;                     /* corrupted or mis-routed  */
    }
    uint8_t alive = (m->data[4] >> 4) & 0x0Fu;
    if (alive == g_sensorHealth.lastAlive) {
        return false;                     /* stale repeat, not fresh  */
    }
    g_sensorHealth.lastAlive = alive;
    g_sensorHealth.age_ms    = 0u;
    g_sensorHealth.valid     = true;

    g_temp_dC = (int16_t)((uint16_t)m->data[0] |
                          ((uint16_t)m->data[1] << 8));
    return ((m->data[4] & 0x01u) != 0u);  /* SensorValid bit          */
}

Fault-handling matrix

This table is the real deliverable. Every row is a failure a reviewer will ask about, and every cell is a decision you have to defend.

Failure Detected by Detection time Response
Sensor node silent Gateway: 0x310 age > 300 ms ≤ 300 ms Fan to 100 % (fail-safe cooling), send 0x200, set DTC
Sensor reports invalid SensorValid = 0 1 cycle Same — an implausible reading is not a low reading
Gateway silent Actuator: 0x311 age > 300 ms ≤ 300 ms Hold last command 1 s, then ramp to the safe default
Actuator silent Gateway: 0x312 age > 300 ms ≤ 300 ms Send 0x200, set DTC, keep transmitting 0x311
Checksum failures Any consumer immediate Discard and count; 5 consecutive = treat as silence
Alive counter frozen Any consumer 2 cycles Producer's task has hung — treat as silence
Bus-off ESR1[BOFFINT] ≤ 1 frame Safe state, rate-limited recovery (module 1), latch after 3
Node reset Its own RCM->SRS at boot Outputs safe before CAN init; report cause in 0x200
Both terminators removed Rising ECR counts ≤ 1 s All nodes reach bus-off independently and go safe

The important asymmetry: the actuator holds the last command for 1 s before defaulting, while the gateway acts within 300 ms. A brief gateway glitch should not slam the fan; a genuinely absent gateway must not leave the fan under stale control forever. Where that boundary sits is a system decision, and writing it down is what makes it reviewable.

Automotive concerns

  • Nodes boot at different times, and that is normal. The gateway sees nothing from the actuator for a few hundred milliseconds after key-on. Start every supervisor in a "not yet valid" state with a startup grace period, distinct from "was valid, went silent" — they deserve different DTCs.
  • Alive counter plus checksum is the minimum for anything that moves an actuator. The checksum catches corruption; the alive counter catches a producer whose task has hung while its DMA or mailbox keeps re-sending the same bytes. Neither alone is sufficient — together they are what an end-to-end protection profile formalises.
  • Include the ID in the checksum. A mailbox configured with the wrong ID, or a copy-pasted transmit routine in another node, produces perfectly valid-looking data under the wrong identifier. Folding the ID in makes that failure loud instead of silent.
  • DMA and CAN compete for attention. If the sensor node scans its ADC by eDMA (module 2), channel priorities and the FlexCAN interrupt priority interact — a DMA error interrupt at the wrong priority can preempt the CAN callback and cost you a FIFO slot. Assign channels and priorities once, in a table, and review them together.
  • Flash writes stall the node. If the gateway stores a DTC while a 0x311 transmission is due, the flash operation blocks for milliseconds and the frame jitters. Queue DTC writes and flush them in the lowest-priority task or at shutdown (module 6), never inline in a fault handler.
  • A UDS session changes the whole network's behaviour. An extended session forcing a fan test overrides the sensor's request, so every node must know that RequestedMode can originate from diagnostics — and the S3 timeout (module 9) must return the network to NET_MODE_RUN, not just the gateway.
  • Sleep is a network decision. NetworkMode = 3 is a request; a node with a pending fault or an active diagnostic session must be able to veto it. Module 5's wakeup sources give you the way back — but only if every node agreed to go down in the first place.
  • One termination is a detectable fault. With a single 120 Ω resistor the bus often still works, until temperature or cable length makes it not. Export ECR error-counter statistics from every node; a node with persistently elevated counts on an otherwise healthy bus is telling you about its own wiring.

Cheat sheet

Item Notes
Topology 3 nodes, one 500 kbit/s bus, 120 Ω at both physical ends only
ID = priority 0x100 mode · 0x200 fault · 0x3100x312 cyclic · 0x7Ex diag
Periods 100 ms cyclic, 500 ms network mode, event faults with a ≥ 100 ms gap
Phasing Offset producers by 10–20 ms so cyclic frames do not collide every cycle
Timeout 300 ms = three missed cycles, for every consumed signal
Protection Alive counter (staleness) and ID-inclusive checksum (corruption)
Latency budget ≈ 41 ms sample → actuator applied; recompute if a queue is added
Bus load ≈ 0.7 % — compute it before anyone proposes a trace frame
Gateway RX RX FIFO, 8-element format-A table, no 0x000 padding entries
Callback rule Copy and re-arm; checksum, alive and range checks belong in the task
Fail-safe Fan to 100 % on lost or invalid temperature — safe direction, not zero
Shared header can_matrix.h compiled by all three nodes — one source of truth
Bench tools 3 × S32K144 EVB (or 2 EVBs + PCAN-USB), candump -t z, cansend

How It Actually Works

Coordinating multiple independent ECUs on one CAN bus works because every node's FlexCAN module runs its own free-running bit-timing state machine, and the network only functions as "one bus" through the arbitration and resynchronization mechanisms covered in the fundamentals module — there is no master clock or master node coordinating anything at the electrical level. Each node's bit-timing logic resynchronizes every recessive-to-dominant edge it observes, using the resync jump width, which is precisely what allows nodes with independently drifting oscillators (different crystals, different temperatures) to stay bit-aligned indefinitely as long as the drift per bit stays within the configured tolerance.

Message-ID allocation across the network is really a priority allocation at the hardware arbitration level: every node's transmit MBs continuously and independently decide "am I highest priority pending" using the same bitwise dominant-wins mechanism, so there is no central arbiter to fail — this is a genuinely distributed real-time scheduling mechanism implemented entirely in each node's comparator hardware, which is why CAN remains deterministic even as nodes are added or removed from the bus live.

Detecting a node dropping off (bus-off, covered by FlexCAN's transmit/receive error counters) is itself hardware-enforced: FlexCAN increments a TX or RX error counter on every detected form/bit/stuff/CRC/ACK error according to the CAN spec's exact counter rules, and once TEC exceeds 255 the module autonomously transitions to Bus-Off and physically stops driving the bus at all — this self-isolation mechanism is what stops one node with a hardware fault (e.g. a shorted transceiver) from permanently jamming a bus that other, healthy nodes still need.

(Described from the ISO 11898-1 CAN specification and FlexCAN reference manual; not measured on physical silicon in this course.)

Exercise

Build the network. (1) Write can_matrix.h and the message catalogue as a document before any node code, and have someone read it back to you — if they can implement byte 4 without asking a question, the table is done. (2) Bring up the sensor node and the gateway first, with candump playing the actuator; confirm 0x310 at 100 ms ±2 ms, 0x311 phased 20 ms behind it, and both alive counters advancing without a skip over ten thousand frames. (3) Add the actuator node with its own tick and tacho capture, then measure the real end-to-end latency: toggle a GPIO in the sensor node when it samples and another in the actuator node when it applies PWM, put both on a scope, and explain any difference from your 41 ms budget. (4) Work through the fault-handling matrix row by row on the bench — unplug the sensor node, freeze the gateway in the debugger, transmit a hand-built frame with a bad checksum, remove a terminator. Each row must produce the documented response within the documented time, and you must observe it, not infer it. (5) Instrument every node with ECR error counters, RX FIFO overflow counts and checksum-failure counts exported in 0x200, then run the network for an hour; any non-zero counter at the end is a defect with an hour of evidence attached.

Stretch goals

  • Add the bootloader and UDS from modules 8 and 9 to the gateway, then reflash it over CAN while the other two nodes keep running. The actuator's hold-then-default behaviour during the reprogramming window is the moment those two modules stop being theory.
  • Move the sensor node's ADC scan to eDMA (module 2) with a ping-pong buffer, and show on a scope that CAN transmission jitter drops because the CPU no longer services per-conversion interrupts.
  • Put one node on FreeRTOS (module 4) with separate CAN-RX, control and diagnostic tasks, and demonstrate that the priority assignment holds the 100 ms period under a deliberately overloaded low-priority task.
  • Implement network sleep and wake (module 5): the gateway requests sleep with NetworkMode = 3, each node acknowledges or vetoes, all three enter VLPS with FlexCAN Pretended Networking armed, and one 0x100 frame wakes the network. Measure one node's current before and after.
  • Add a fourth node from a different codebase — a Raspberry Pi with a CAN HAT simulating the actuator in Python. If your matrix is good, that node integrates from the document alone, which is exactly the test the document exists to pass.
  • Introduce CAN FD on the same topology (module 7's migration notes apply): raise the data phase to 2 Mbit/s, extend 0x310 to a 64-byte payload carrying a sensor history, and recompute the bus load and the latency budget from scratch.