10 · Project — Design a CAPL Test Script for a Simulated ECU Signal

This capstone pulls together every Level 1 module into one deliverable: a CAPL script that simulates a sensor node, a threshold-driven warning signal with hysteresis, a UDS-style diagnostic reset, and a documented test case set proving it all behaves correctly — the same shape of work a junior automotive test engineer does in their first real project.

About this project

As with every hands-on module in this course, this CAPL script is a carefully reviewed worked example for technical accuracy against real, documented CAPL conventions — it has not been compiled or run against a live CANoe instance. Treat it as a template to adapt once you have real tool access, and verify it against your own project's CANoe/CAPL version and database before relying on it.

The scenario

You're testing a fuel level sensor node that:

  • Transmits FuelLevelStatus every 100 ms: a FuelLevelPct signal (0-100%, 1% per raw unit), a LowFuelWarning flag, and a 4-bit AliveCounter.
  • Raises LowFuelWarning when FuelLevelPct drops below 10%, and clears it only once FuelLevelPct rises above 15% (hysteresis, per Module 8's exercise on exactly this pattern).
  • Listens for a DiagnosticResetRequest message (standing in for a UDS-style diagnostic trigger from Module 6) and, on receiving it, resets its internal alive counter to 0.

Step 1 — the CAPL simulation node

variables
{
  message FuelLevelStatus       statusMsg;
  message DiagnosticResetRequest resetReq;   // received, not sent by this node

  msTimer cycleTimer;
  byte    aliveCounter;
  int     fuelLevelPct;     // current simulated fuel level, 0-100
  byte    warningActive;    // 0 or 1 - holds hysteresis state
}

on start
{
  aliveCounter  = 0;
  fuelLevelPct  = 50;     // start at a nominal, safe level
  warningActive = 0;

  setTimer(cycleTimer, 100);
}

on timer cycleTimer
{
  // Hysteresis logic: activate below 10, deactivate only above 15.
  if (fuelLevelPct < 10)
  {
    warningActive = 1;
  }
  else if (fuelLevelPct > 15)
  {
    warningActive = 0;
  }
  // Between 10 and 15 inclusive: warningActive keeps its previous value.

  statusMsg.FuelLevelPct  = fuelLevelPct;
  statusMsg.LowFuelWarning = warningActive;
  statusMsg.AliveCounter  = aliveCounter;
  output(statusMsg);

  aliveCounter = (aliveCounter + 1) % 16;
  setTimer(cycleTimer, 100);
}

on message DiagnosticResetRequest
{
  write("DiagnosticResetRequest received - resetting alive counter.");
  aliveCounter = 0;
}

A CAPL test harness would drive fuelLevelPct directly (as shown below) to control the scenario deterministically; a real sensor node would instead compute it from a simulated physical model or a real ADC reading, per the S32K course's ADC module.

Step 2 — the CAPL test script

A separate CAPL program, acting as the tester, drives fuelLevelPct through the exact boundary sequence from Module 8's exercise and checks LowFuelWarning at each step:

variables
{
  msTimer stepTimer;
  int     testStep;
}

on start
{
  testStep = 0;
  setTimer(stepTimer, 500);   // allow one full cycle to settle before checking
}

on timer stepTimer
{
  switch (testStep)
  {
    case 0:
      write("Step 0: set fuel level to 9%% (expect warning ON)");
      fuelLevelPct = 9;
      break;

    case 1:
      if (warningActive == 1)
        write("PASS: TC-FUEL-01 - warning ON at 9%%");
      else
        write("FAIL: TC-FUEL-01 - warning OFF at 9%%, expected ON");

      write("Step 1: set fuel level to 12%% (expect warning still ON - hysteresis)");
      fuelLevelPct = 12;
      break;

    case 2:
      if (warningActive == 1)
        write("PASS: TC-FUEL-02 - warning still ON at 12%% (hysteresis holds)");
      else
        write("FAIL: TC-FUEL-02 - warning OFF at 12%%, expected ON (hysteresis broken)");

      write("Step 2: set fuel level to 16%% (expect warning OFF)");
      fuelLevelPct = 16;
      break;

    case 3:
      if (warningActive == 0)
        write("PASS: TC-FUEL-03 - warning OFF at 16%%");
      else
        write("FAIL: TC-FUEL-03 - warning still ON at 16%%, expected OFF");

      write("Test sequence complete.");
      return;   // stop re-arming the timer - test finished
  }

  testStep = testStep + 1;
  setTimer(stepTimer, 500);
}

This mirrors exactly the "trickiest boundary case" from Module 8's exercise — 9% → 12% → 16% — with the middle step being the one that actually proves the hysteresis logic works, not just the two clear-cut thresholds.

Step 3 — the documented test cases (traceability)

Test Case ID Title Steps Expected result Requirement
TC-FUEL-01 Warning activates below 10% Set FuelLevelPct = 9 LowFuelWarning == 1 within 100 ms REQ-FUEL-002
TC-FUEL-02 Warning stays active in the hysteresis band Set FuelLevelPct = 12 after TC-FUEL-01 LowFuelWarning == 1 (unchanged) REQ-FUEL-003
TC-FUEL-03 Warning deactivates above 15% Set FuelLevelPct = 16 after TC-FUEL-02 LowFuelWarning == 0 within 100 ms REQ-FUEL-003
TC-FUEL-04 Alive counter resets on diagnostic request Send DiagnosticResetRequest, then observe next FuelLevelStatus AliveCounter == 0 in the next transmitted frame REQ-FUEL-005
TC-FUEL-05 Alive counter increments and wraps Observe 20 consecutive frames Counter increments by 1 each frame, wraps 15 -> 0 REQ-FUEL-006

A minimal traceability matrix:

Req ID Requirement summary Test cases Status
REQ-FUEL-002 Warning activates below 10% TC-FUEL-01 Covered
REQ-FUEL-003 Warning deactivates only above 15% (hysteresis) TC-FUEL-02, TC-FUEL-03 Covered
REQ-FUEL-005 Alive counter resets on diagnostic reset request TC-FUEL-04 Covered
REQ-FUEL-006 Alive counter increments and wraps correctly TC-FUEL-05 Covered
REQ-FUEL-004 Warning state must be reported correctly to the instrument cluster GAP — not testable at this node's level alone; needs integration test with the cluster ECU

That last row is deliberate: a good traceability matrix surfaces real gaps, including ones that are out of scope for a single node's test script and need to move up the V-model to integration test.

What this project demonstrates, mapped to Level 1

Module Concept used here
1 — V-model This script sits at unit/component test; TC-FUEL-04's gap points at integration test
2-3 — CAN fundamentals & frames The signals being tested are carried in real CAN frame fields
4 — CANoe This script and its test harness would run inside a CANoe configuration
5 — CAPL Event handlers, on timer, on message, cyclic sender, alive counter pattern
6 — UDS diagnostics DiagnosticResetRequest stands in for a UDS-style diagnostic trigger
8 — Test case design Boundary value analysis with hysteresis, fully documented test cases, traceability
9 — Standards This is exactly the kind of evidence an ASPICE SWE.4 assessment or an ISO 26262 safety case would ask to see

How It Actually Works: why the 500 ms step delay isn't arbitrary

Step 2's test script waits 500 ms between driving fuelLevelPct and checking warningActive, and that number is doing real, specific work tied directly to Module 5's event-queue mechanics — it isn't a convenient round number.

Both CAPL programs (the simulated sensor node and the test script) run inside the same CANoe measurement, sharing one event queue and one single-threaded runtime. When the test script sets fuelLevelPct = 9, that variable write takes effect immediately in memory, but it does nothing observable on the bus until the sensor node's own cycleTimer next fires — and that timer runs on its own independent 100 ms schedule, started at on start with no relationship to when the test script happens to change the variable. In the worst case, the variable change lands just after a cycle has already fired, meaning the sensor node won't transmit the new value for nearly a full 100 ms. The test script's warningActive check itself only reflects whatever the sensor node last computed and transmitted — so checking too early reads stale state and produces a false FAIL, not because the hysteresis logic is wrong, but because the checking script outran the system under test's own cycle time.

The 500 ms wait is really "worst-case cycle misalignment (just under 100 ms) plus several cycles of margin for reliable observation," and it's the same reasoning Module 8's fully worked test case used when it specified "within one signal update cycle (≤ 100 ms)" as part of the expected result rather than an instantaneous check. Generalizing this: any CAPL test script driving a cyclic simulation must wait at least one full cycle period past the moment it changes an input, and a robust script does this by explicitly re-arming its own check after the DUT's documented cycle time, never by guessing a delay that happens to work in one test run — a script using, say, 50 ms here (less than one full cycle) would pass or fail nondeterministically depending on exact timer phase alignment, which is exactly the kind of flaky, timing-based test failure a competent automotive tester learns to recognize on sight.

Exercise

Extend this project with one more requirement: REQ-FUEL-007 — if the sensor node's FuelLevelStatus frame stops arriving for more than 300 ms (simulating a bus fault or node failure), a separate consumer node (e.g., the instrument cluster) shall set an internal fuelSignalLost flag and display a generic "check fuel system" fault rather than trusting a frozen LowFuelWarning value.

  1. Write the CAPL variables block and on message / on timer handlers for the consumer node's signal-timeout watchdog, following the exact pattern from Module 5.
  2. Write two fully documented test cases: one proving the flag sets correctly after 300 ms of silence, and one proving it clears correctly the moment FuelLevelStatus resumes.
  3. Add both new test cases to the traceability matrix above, and identify whether REQ-FUEL-007 is better tested as a unit test on the consumer node alone, or requires the sensor node included too — justify your answer using the V-model framing from Module 1.