06 · Fault Injection Testing

Module 4 tested safety mechanisms by manipulating signal values on the bus — a valid technique, but it can't reach every fault class a real ECU must survive. This module covers the broader taxonomy of fault injection — electrical, communication, and software-level — and where each technique's limits are, especially the limits of what CAPL alone can simulate.

About this module

No physical fault-injection hardware (relay boxes, breakout boxes, programmable power supplies) was used to produce this content. The taxonomy and CAPL patterns below reflect documented HIL/fault- injection practice — treat every snippet as an architectural reference, and note explicitly where real hardware is required and CAPL cannot substitute.

The fault taxonomy

Class Example Can CAPL alone inject it?
Signal-level (message content) A CAN signal reports an implausible value Yes — setSignal() on the simulated node
Communication-level A frame stops arriving, arrives late, or is malformed (bad CRC, bad DLC) Partially — CANoe can suppress/delay frames and corrupt payload; some corruption (physical-layer bit errors) needs a real network fault injector
Electrical-level A sensor line opens (open circuit), shorts to ground, shorts to battery voltage No — needs a physical relay/switch box (a "breakout box") wired between the ECU and its harness
Power-level Voltage sag, brownout, ignition-cycle glitch during a write operation No — needs a programmable power supply capable of scripted voltage profiles
Software/timing-level A task misses its deadline, a watchdog isn't fed Sometimes, if the ECU exposes a debug/test hook; otherwise needs instrumented target debugging, out of scope for bus-level testing

The taxonomy matters because a test plan that only ever exercises signal-level faults (the easiest to script) can systematically miss entire classes of real-world failure — an open sensor wire behaves very differently from that same sensor reporting an implausible value, and a safety mechanism designed for one may not catch the other.

Communication-level fault injection in CAPL

// Illustrative — CANoe's fault-injection block/CAPL functions vary
// by version; verify exact function names against your installation.
testcase tc_MissingFrameTriggersTimeout()
{
  testCaseTitle("ECU flags communication loss when expected frame stops arriving");
  dword t0, t1;

  BlockMessage(WheelSpeedFL); // suppress transmission entirely, simulating a dead sender
  t0 = timeNowNS() / 1000000;

  testWaitForSignal(CommTimeoutFault_WheelSpeedFL, 1, 500);
  t1 = timeNowNS() / 1000000;

  testStepCheck("comm timeout fault flagged within spec", (t1 - t0) <= 500);
  UnblockMessage(WheelSpeedFL); // always restore normal traffic before the next testcase
}

testcase tc_CorruptedDlcRejected()
{
  testCaseTitle("Frame with wrong DLC vs. DBC definition is rejected, not misparsed");
  message WheelSpeedFL msg;
  msg.DLC = 4; // DBC defines 8 — deliberately wrong
  msg.byte(0) = 0xFF;
  output(msg);

  testWaitForTimeout(100);
  testStepCheck("no valid wheel speed update accepted from malformed frame",
                 getSignal(WheelSpeedFL_Value) == gLastKnownGoodValue);
}

tc_MissingFrameTriggersTimeout restores normal traffic explicitly at the end — the same "always undo what you injected" discipline as Module 4's calibration restore, generalized to any fault-injection technique: leaving a blocked message in place corrupts every subsequent testcase in the run.

Why electrical-level faults need real hardware

A sensor reporting 0xFF 0xFF (an implausible value CAPL can easily simulate) and a sensor whose signal wire has physically opened produce different electrical symptoms an ECU's front-end circuitry may distinguish — pull-up/pull-down behavior, voltage rail sag, ADC saturation versus floating input. A safety mechanism specifically designed to detect an open circuit via electrical characteristics (not just implausible values) cannot be validated by CAPL signal manipulation alone — it requires a breakout box or fault-injection relay bank physically wired into the ECU's harness, under HIL rig control, to open/short/ground specific pins on command.

Typical breakout-box fault types (hardware-level, NOT reachable from CAPL):
  - Open circuit      (pin disconnected)
  - Short to ground   (pin pulled to 0V)
  - Short to battery  (pin pulled to Vbatt, ~12V/24V)
  - Short to adjacent pin (cross-short between two harness pins)

A well-structured HIL test plan (Module 10) explicitly separates test cases that a CAPL-only rig can execute from those that require this class of hardware, so gaps in physical fault-injection coverage are visible and tracked rather than silently absent.

Fault injection campaigns: coverage over one-off checks

A mature fault-injection practice doesn't test faults ad hoc — it maintains a fault matrix: every safety-relevant signal or interface, crossed with every applicable fault type, with a tracked pass/fail/not-yet-tested status:

Signal/Interface Implausible value Frame timeout Open circuit Short to ground Short to battery
WheelSpeedFL Tested — Pass Tested — Pass Not yet tested Not yet tested Not yet tested
BrakePedalPosition Tested — Pass Tested — Fail (bug filed) Tested — Pass Not yet tested N/A (digital signal)

This matrix is itself a traceability artifact (Module 8) and typically maps directly to entries in the safety case's FMEA (Failure Mode and Effects Analysis) — each cell should trace back to a specific failure mode the FMEA identified as needing a detection mechanism.

Cheat sheet

Concept Key point
Fault taxonomy Signal, communication, electrical, power, software/timing — each needs different tooling
CAPL's ceiling Signal and much communication-level faults; not electrical or power-level
Restore after injecting Every fault injection needs an explicit undo before the next testcase
Fault matrix Track signal × fault-type coverage explicitly, tied to the FMEA

How It Actually Works: why open and short produce different voltages, not just different labels

The reason electrical faults need real hardware isn't only "CAPL can't touch wires" — it's that an ECU's analog front-end circuit is designed to make open circuit and short circuit land at electrically distinguishable voltages, and a good safety mechanism is built to exploit exactly that separation, which is invisible if you only ever manipulate the decoded signal value.

A typical analog sensor input includes a pull-up (or pull-down) resistor on the ECU side, sized so that when the sensor is disconnected (open), the ADC input floats to a known rail-referenced voltage — often near 0 V or near supply, depending on the pull direction — rather than floating to an arbitrary, unpredictable level. A short to ground pulls the same node hard to 0 V regardless of the pull-up's value; a short to battery voltage pulls it to roughly 12-14 V (well above the sensor's normal operating range, and often above the ADC's own input protection threshold). A well-designed range check (Module 4's safety mechanism table) sets its plausible window specifically inside the gap those three failure voltages create — for example, sensor range 0.5-4.5 V with open-circuit pull-up landing the node at 5.0 V and short-to-ground landing it at 0.0 V — so the ECU can distinguish "sensor disconnected" from "sensor shorted" from "sensor working but reporting a low value" purely from which side of the plausible band the voltage lands on, without any extra circuitry beyond the resistor and the ADC.

This is exactly why a breakout box's relay bank has to physically reproduce these three distinct electrical states (open, short-to-ground, short-to-battery) rather than just three abstract "fault codes" — each one drives the ECU's front-end to a genuinely different voltage that the ECU's own hardware, not its software, is what determines whether the result even reaches the microcontroller's ADC as a valid reading versus a clamped/protected value, and a fault-injection test that only mimics this by writing an out-of-range signal value bypasses that entire front-end behavior — proving the software's range-check logic works without ever proving the actual hardware distinguishes the fault the way the design intended.

Exercise

  1. For BrakePedalPosition in the fault matrix, explain why "short to ground" and "short to battery" are meaningful hardware-level faults to test but "N/A" is marked for one of them if the signal is digital (0/1) rather than analog — under what physical circumstance would a digital signal's short-to-battery still be meaningful to test?
  2. tc_CorruptedDlcRejected assumes gLastKnownGoodValue is tracked elsewhere. Write the CAPL to maintain it correctly (updated only on an ECU-acknowledged valid frame, not merely a well-formed one).
  3. Given the taxonomy table, design a one-page test plan section listing, for a fictional tire-pressure-sensor ECU, which fault types you'd request breakout-box hardware for and which you can cover with CAPL alone — with a one-line justification per row.